發表論文
| Publications:- Tung-Ho Wu, Jeng-Fong Chiou, Ron Zhu, Kuang-Wei Huang, Pei-Fong Wong, Sam Tung, K.S. Clifford Chao, Jo-Ting Tsai (2006 Therapeutic Radiology and Oncology journal) To Reduce Dose Inhomogeneity at Neck Junction by Using a Rotating Collimator on IMRT-Treated Head-and-neck Cancer Patients. [獲選為年度最佳論文]
- Yu-Cheng Kuo, Tung-Ho Wu, Tao-Sang Chung, Kuang-Wei Huang, K.S. Clifford Chao, Wen-Chuan Su, Jeng-Fong Chiou. (2006 Therapeutic Radiology and Oncology journal) Does two-phased intensity-modulated radiotherapy further reduce radiation doses received by parotid glands on the patients of head and neck cancer with enlarged neck lymph nodes
Posters:
- Tung-Ho Wu, M.S., Jeng-Fong Chiou, M.D., K-W Huang, M.D., Tung-Ho Chen, Pai-Chia Lin, Yu-Cheng Kuong, M.D. (2004 annual meeting poster) Dose evaluation of step-and-shoot IMRT with incorrect leaf delivering
- Tung-Ho Wu, M.S., Ron Zhu, Ph.D., Pei-Fong Wong, M.S., Sam Tung, M.S., K.S. Clifford Chao, M.D., Jeng-Fong Chiou,, M.D., Kuang-Wei Huang, M.S., (2005 annual meeting poster) A new technique for reducing junction inhomogenity issue for head-and-neck cancer patients treated with IMRT
- Tung-Ho Wu, M.S., Ron Zhu, Ph.D., Pei-Fong Wong, M.S., Sam Tung, M.S., K.S. Clifford Chao, M.D., Jeng-Fong Chiou,, M.D., Kuang-Wei Huang, M.S., (2005 annual meeting poster) A new technique for reducing junction inhomogenity issue for head-and-neck cancer patients treated with IMRT
- Tung-Ho Wu, M.S., Ron Zhu, Ph.D., Pei-Fong Wong, M.S., Sam Tung, M.S., K.S. Clifford Chao, M.D., Jeng-Fong Chiou,, M.D., Kuang-Wei Huang, M.S., (2005 annual meeting poster) A study of whole-neck IMRT in head and neck cancer to reduce field number and treatment time
- Tung-Ho Wu, M.S., Kuang-Wei Huang, M.S., Tung-Ho Chen, Shih-Ting Tsai, M.S., Mei-Ling Chen, Shu-Pao Lin, Pai-Chia Lin, Jeng-Fong Chiou, M.D., (2006 annual meeting poster) The comparison of setup error in Radiotherapy : image guided、spherical marker guided and laser alignment
- Tao-sheng Chung, Yung-Chang Lien, Jeng-fong Chiou, Jo-Ting Tsai, Yu-Cheng Kuo, Kuang-Wei Huang, Chiu-Ping Chen, Tung-Ho Wu, Shih-ting Tsai, Tung-ho Chen. (2006 annual meeting poster) Image guide radiotherapy system using fiducial implant on lung carcinoma
- Tung-Ho Wu, M.S., Kuang-Wei Huang, M.S., Jeng-Fong Chiou, M.D. (2007 annual meeting poster) The application and comparison of Argus system in IMRT QA process
- Tung-Ho Wu, M.S., Yu-Chen Kuo,M.D., Hsiao-Wei Yu, M.S., Tung-Ho Chen, Chia-Jen Kuo,M.D., Kuang-Wei Huang, M.S., Po-Chen Kuo, Jeng-Fong Chiou, M.D. (2008 annual meeting poster) The NTCP Comparisons of IMRT and 3DCRT for Huge Hepatocellular Carcinoma
- Tung-Ho Wu, Han-Cheng Chu, Chia-Lin Chen, Chen-Hon Hsu, Chung-Yi Wang. (2010 AOCMP) Daily Image Guidance With Cone-Beam Computed Tomography for Evaluating Systematic Error and Random Error of IG-IMRT patients: A Retrospective Study
- Tung-Ho Wu, Yo-Han Chen, Chung-Yi Wang (2010 AOCMP) Dosimetric Validation of a Commercial Monte Carlo Based VMAT Planning System
- Tung-Ho Wu, Chia-Ling Chen, Chen-Hon Hsu, Han-Cheng Chu, Yo-Han Chen, Yi-Hsien Lin, Chung-Yi Wang (2011 annual meeting poster) Use MV portal image device to routine verify MLC position accuracy
- Tung-Ho Wu, Yo-Han Chen, Yi-Hsien Lin, Chung-Yi Wang (2011 annual meeting poster) Patient-specific Quality Assurance for VMAT and IMRT Treatment by Using 2D-Array Seven29 and Octavius Phantom [獲選為年度壁報論文佳作]
- Tung-Ho Wu, Yo-Han Chen, Yi-Hsien Lin, Chung-Yi Wang (2011 annual meeting poster) Comparison of Monaco VMAT with Xio IMRT for High-Risk Prostate Cases: Plan Quality, Delivery Efficiency and accuracy
- Tung-Ho Wu, Yo-Han Chen, Yi-Hsien Lin, Chung-Yi Wang (2011 CSMP annual meeting poster) The Preliminary Study: Dosimetric Comparison between Clarkson, Convolution, Superposition, XVMC, and Pencil-beam Dose Calculation Algorithm in inhomogeneity Region [獲選為年度壁報論文第二名]
- Tung-Ho Wu, Ping-Fang Tsai, Shen-Hao Lee, Chien-Yi Yeh, Ji-Hong Hong, Chen-Kan Tseng, Shinn-yn Lin (2013 CSMP annual meeting poster) Whole-Brain Radiotherapy with Hippocampus-Sparing: A Comprehensive Study using Linac-based RapidArc and Intensity-Modulated Radiotherapy Technique [獲選為年度壁報論文第一名]
- Tung-Ho Wu, Chien-Yi Yeh, Ji-Hong Hong, Ping-Chin Pai, Chen-Kan Tseng, Chun-Chieh Wang (2013 CSMP annual meeting poster) Dosimetric Comparison of HybridArc vs IMRT techniques in Radiosurgery and EBT3 film validation for HybridArc
Trainning:
- 99年度電腦斷層掃描儀醫療暴露品質保證實作訓練
- 102年度電腦斷層掃描儀醫療暴露品質保證實作訓練
- 102年度人體試驗研究人員講習班(林口醫研字0235號)
|