The cumulative sensitivity and specificity of ICT







































         Of the 156 patients enrolled, 91 (58%), 64 (41%) and 72


         (46%) were positive to the ICT kit, viral culture and


         RTPCR, respectively. The laboratory-confirmed infection

         with either positive EV71 culture or RTPCR was used as

         the          diagnostic                standard.                The         sensitivity                 and


         specificity of ICT kit were 84% and 77% (Figure 2). In


         the study, virus culture and RTPCR gave a relatively

         lower sensitivity but higher specificity. The patient

         age       didn’t            affect the                performance               of      ICT,        virus


         culture and RTPCR. However, a low sensitivity of ICT


         kit was noted before the second day of disease onset

         (Figure 2).In the instruction of the ICT kit, not only

         whole blood but the serum and plasma are acceptable for


         running the test. We compared the results of ICT kit


         from        whole         blood         and       plasma          samples           in      the        same

         patients, and 100% compatibility was noted.